Application Tag Commands
84 Command Set
If Option=0x00 or 0x01 were used then the unused Tag Singulation Fields must be
removed from the request.
The response to this command varies depending upon the number of bits in the tag EPC
of the tag found. The general response format is shown here:
Get Tag EPC and Meta Data
In addition to getting the tag EPC value returned you can also get Tag Read Meta Data for
the found tag. This version of Read Tag Single requires bit 4 of the Option flag to be set
and takes an additional Metadata Flags field which defines what metadata will be
returned The following table lists the supported values for these fields.
FF 0A 21 03 E8 03 00 00 00 20 10 12 34 E5 AC
SOH Length OpCode Timeout (ms) Option Select Address Select
Data
Length
Select Data CRC
FF M+3 21 00 00 03 M bytes ?? ?? ?? ??
SOH Length OpCode Status Option EPC TagCRC CRC
Zobrazit stránku 83